Next: Limitations
Up: Calculation of Vibrational Frequencies
Previous: Calculation of Vibrational Frequencies
Contents
Index
- Both aoforce and even more Numforce require well converged
SCF-/DFT-calculations (e.g.
$scfconv 8
and jobex [-ri] -gcart 4
).
- The maximum core memory the program aoforce is allowed to
allocate should be defined in the data group $maxcor; the
recommended value is about 50% of the available (physical) core
memory (in case of RI-calculations subtract the memory specified in
$ricore).
- To start aoforce in the lowest eigenvalue search mode, use
the keyword $les. For its use as well as other keywords
dealing with the calculation of only some irreps, see the
Referenceguide part of this manual.
- Numforce additionally requires the file
gradient
and
will not work, if the calculation is not done at a stationary point
of the molecular total energy. For reliable results, always use
Numforce with the option -central
(i.e. central
differences) and be aware of effects due to the step length (option
-d
real;, default value is 0.02a.u.).
It is strongly recommended to use Numforce in DFT calculations
only with the option weight derivatives in $dft,
since this provides more accurate gradients and thus frequencies,
see Section 15.2.8.
- The Numforce script can be run for different levels of
theory, which means that the binaries it calls have to be specified
additionally. To perform calculations using the RI approximation,
call Numforce with the option
-ri
. MP2 and CC2
calculations are requested via the options -level mp2
and
-level cc2
, respectively. To select the correct option(s),
use the explanations you get by calling NumForce -h
.
For a review of theory and implementation see refs.
[117,118].
Next: Limitations
Up: Calculation of Vibrational Frequencies
Previous: Calculation of Vibrational Frequencies
Contents
Index
TURBOMOLE