nohup NumForce -ex
n > force.out &
where n is the number of the excited state in C1
symmetry. In order to determine n, it is recommended to perform
an escf calculation in C1 symmetry. Note that numerical
calculation of excited state force constants is likely to fail
if there are other states nearby (in C1), because the roots may
flip when the molecule is distorted. Note also that it may be
necessary to include higher excited states (using $exopt, see
above) in C1 calculations of molecules with higher symmetry in
order to enforce convergence to the correct state. In any case, it
should be checked that the energy change due to the displacements
(available in the numforce/KraftWerk/*.log
files) is reasonably
small.
For a Numforce run, the convergence criteria should be tightened. It is recommended to use at least
$scfconv 8in all Numforce calculations. Other Numforce options such as
-central
, -d
, -np
work in exactly the same way as
they do for ground states.